22
© 1999 Directed Electronics, Inc. N381 9/99
2-8 IGNITION LOCK WITH DOOR OPEN OFF/ON:
If a door is open when the ignition is turned on, this fea-
ture will prevent the doors from locking. Ignition controlled door locks must be selected in Feature 1-3. If the
ignition lock safety wire (H3/10) has been connected, ignition lock with door open should be turned on.
2-9 PANlC MODE ON/OFF:
This feature will disable the panic mode entirely. This is mainly for countries other
than the USA, where there are laws prohibiting panic mode.
2-10 DOOR SENSOR BYPASS CHIRP ON/OFF:
This feature controls the error chirp that is generated
if the system is armed with the door trigger active. This is useful in vehicles that have a long dome light
delay after the door has been closed. If the system is armed before the dome light has turned off, the
security system will generate the door trigger error chirp. If this error chirp is not desired, use this feature
to disable the door open error chirp. If the bypass chirp is turned off, no bypass chirp will be generated,
even if a door is accidentally left open.
Menu #3- Auxiliary Channel Outputs
3-1 CHANNEL THREE VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30, 60, OR 90 SEC-
OND TIMED:
Channel 3 can be programmed for these output configurations.The unit is set to the default
validity output. To change the configuration, use Button II to toggle to the different settings.
3-2 CHANNEL FOUR VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30, 60, OR 90 SEC-
OND TIMED:
Channel 4 can be programmed for these output configurations.The unit is set to the default
validity output. To change the configuration, use Button II to toggle to the different settings.
3-3 CHANNEL FIVE VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30, 60, OR 90 SECOND
TIMED:
Channel 5 can be programmed for these output configurations.The unit is set to the default valid-
ity output. To change the configuration, use Button II to toggle to the different settings.
3-4 CHANNEL SIX VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/ TIMED:
Channel 6 can
be programmed for these output configurations. The unit is set to the default validity output. To change
the configuration, use Button II to toggle to the different settings. If the timed option is selected the default
setting is 15 seconds. To change the timed output, see
Feature
3-5.
3-5 CHANNEL SIX DURATION 5/10/15/20/25/30 SECONDS:
If Channel Six is programmed for a timed out-
put in Feature 3-4, it will output for 15 seconds. It is possible to select any time from 5-30 seconds in 5 sec-
ond increments. Each time Channel Two is pressed, the duration of the output is increased by 5 seconds. The
unit will chirp indicating the number of 5 second increments that have been selected (4 chirps would indicate
20 seconds). Once the unit chirps 6 times, the next input from the transmitter cycles the output back to 1 chirp
setting (5 seconds). If using the DEI Bitwriter or Techsoft programmer the timed output can be programmed
from 1-90 seconds.
3-6 CHANNEL SEVEN SECOND UNLOCK/STANDARD CHANNEL:
The BLUE wire (H3/7) is usually
used to progressively unlock the doors of the vehicle. Pressing the disarm button again within 15 sec-
onds of disarming will generate a (-) pulse on the BLUE wire. If programmed for second unlock, the wire
will also output a pulse when the ignition controlled door lock feature unlocks the door. If this output is
not used to progressively unlock the doors, it can be used as a standard channel output. Programming
the unit for standard channel output will prevent an output from occurring whenever the ignition is turned
off. The unit will no longer treat the output as a door lock output, but instead as a standard output.
3-7 DOUBLE PULSE UNLOCK OFF/ON:
Some vehicles require two pulses on a single wire to unlock the
doors. When the double pulse unlock feature is turned on, the on-board unlock relay will supply two unlock
pulses.
3-8 HORN HONK OUTPUT FLASHING/CONSTANT:
In the default setting the horn honk output (H3/6
BROWN) will provide a flashing output to honk the horn in the full triggered sequence. This output can also be
programmed to honk the horn constantly during the full triggered sequence.
3-9 DISARM WITH CHANNEL TWO ON/OFF:
If programmed ON the security system will disarm whenever
Channel Two is activated with the remote transmitter. This is useful if Channel Two is used for trunk release.
When the trunk is opened the system will disarm preventing the alarm from triggering.
3-10 GWA IN VALET MODE ON/OFF:
If this feature is turned on, the ground-when-armed output will be active
when the doors are locked with the transmitter whenever the system is in valet mode. This can enable the
starter kill relay, even in valet mode.