Vista de página 32
DC
S
11 % Diagnosis coverage DC
S
= λ
sd
/(λ
sd
+ λ
su
)
DC
D
82 % Diagnosis coverage DC
D
= λ
dd
/(λ
dd
+ λ
du
)
T
Diagnosis
Diagnosis test period 100 sec
MTBF = MTTF + MTTR 1.59x10
6
h
max. useful life of the measuring system for the safety
function
approx. 10 years
Single channel architecture
SIL2 (Safety Integrity Level)
HFT = 0 (Hardware Fault Tolerance)
Mode switch is set to "max"
PFD
avg
T
Proof
= 1 year
T
Proof
= 5 years
T
Proof
= 10 years
< 0. 008 x 10
-2
< 0. 039 x 10
-2
< 0. 077 x 10
-2
PFH [1/h] <1.8 x 10
-8
/h
Mode switch is set to "min"
PFD
avg
T
Proof
= 1 year
T
Proof
= 5 years
T
Proof
= 10 years
< 0. 016 x 10
-2
< 0. 078 x 10
-2
< 0. 156 x 10
-2
PFH [1/h] <3.6 x 10
-8
/h
SIL2 (Safety Integrity Level)
HFT = 0 (Hardware Fault Tolerance)
Mode switch is set to "max"
PFD
avg
T
Proof
= 1 year
T
Proof
= 5 years
T
Proof
= 10 years
< 0. 019 x 10
-2
< 0. 093 x 10
-2
< 0. 186 x 10
-2
PFH [1/h] < 4. 3 x 10
-8
/h
Mode switch is set to "min"
Genera l data
Architecture 1 oo1D - Overll
protection
Architecture 1 oo1D - Dry run
protection
Functional safety
OPTISWITCH 3100 C - with two-wire output 33
29955-EN-060112
Vista de página 32