Directed Electronics 3100 Instruções de Operação Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 48
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
3 Remove approx. 10 cm (4 in) of the cable mantle, strip
approx. 1 cm (0.4 in) insulation from the ends of the
individual wires
4 Insert the cable into the sensor through the cable entry
5 Lift the open ing levers of the terminals with a screwdriver
(see following illustration)
6 Insert the wire ends into the open terminals according to
the wiring plan
7 Press down the opening levers of the terminals, you will
hear the terminal spring closing
8 Check the hold of the wires in the terminals by lightly
pulling on them
9 Tighten the compression nut of the cable entry, the seal
ring must completely encircle the cable
10 Screw the housing cover back on
The electrical connection is nished.
Fig. 7: Connection steps 5 and 6
5.3 Wiring plans, single chamber housing
The following illustrations apply to the non-Ex as well as to the
EEx d version .
OPTISWITCH 3100 C - with two-wire output 15
Connecting to power supply
29955-EN-060112
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 47 48

Comentários a estes Manuais

Sem comentários