4 PSS EVE0105 A-(en)
Air output l
n
/h (scfh)
at max. deviation, single and double acting:
Supply air
pressure
bar (psig)
1.4
(20)
2
(30)
4
(60)
6
(90)
7
(105)
with spool
valve
3400
(120)
4300
(151)
7200
(254)
10000
(350)
11400
(400)
with
booster
code F, G
18 000
(636)
24 000
(847)
40 000
(1 492)
55 000
(1 942)
-
with
booster
code H
36 000
(1 271)
48 000
(1
695)
80 000
(2
825)
110 000
(3 884)
The listed values are simplified. The exact
values can be determined using the following
formulas:
single acting and double acting:
P in bar: Qout= (Psup + 1)*1500 [Nl/h]
P in psi: Qout= (Psup+15)*0.06 [scfm]
with booster
single acting, doubled air capacity:
P in bar: Qout= (Psup +1)*21000 [Nl/h]
P in psi: Qout= (Psup+15)*0.84 [scfm]
with Spool Valve,
single acting and double acting:
P in bar: Qout= (Psup + 1)*2300 [Nl/h]
P in psi: Qout= (Psup+15)*0.092 [scfm]
FUNCTIONAL SPECIFICATIONS (common data for all versions)
Travel range
Stroke range ............8...70mm(0.3...2.8in),
and . . 60 ... 120 mm (2.4 ... 4.7 in),
and . . 100 ... 260 mm (3.9 ... 10.2 in)
Rotation angle range ......upto95º
(without mechanical stop)
Supply
With spool valve .......1.4...7bar(20...105psig)
Outputtoactuator ........0to~100%ofsupply air
pressure (up to 5.5 bar at
6 bar supply air pressure)
Air supply
1)
.............according to ISO 8573-1
Solid particle size and density class 2.
Oilrate ................class3
For air supply, we recommend a good quality coalescing
filter or filter regulator.
Response characteristic
2) 3)
Sensitivity ..............<0.1%oftravelspan
Non-linearity (terminal
based adjustment) ........<0.4%oftravelspan
Hysteresis..............<0.3%oftravelspan
Supply air dependence.....<0.1%/1bar(15psi)
Temperatureeffect........<0.3%/10K
Mechanical vibration
10 to 60 Hz up to 0.14 mm,
60to500Hzupto2g .....<0.25%oftravelspan
1) Pressure dew point 10 K under ambient temperature
2) Data measured according to VDI/VDE 2177
3) With stroke 30 mm and lever length 90 mm
Air consumption (steady state) l
n
/h (scfh)
Supply air
pressure
bar (psig)
1.4
(20)
3
(45)
6
(90)
single
acting
100
(3.5)
110
(3.9)
150
(5.3)
double
acting
200
(7.0)
220
(7.8)
300
(10.6)
The listed values are simplified. The exact values can be
determined using the following formulas:
single acting;
P in bar: Qcon= (Psup+1)*20 + Pout*60 [Nl/h]
P in psi: Qcon= (Psup+15)*0.0008 + Pout*0.0024 [scfm]
double acting:
P in bar: Qcon= (Psup + 1)*110 [Nl/h]
P in psi: Qcon= (Psup + 15)*0.0044 [scfm]
Qcon Max. Air consumption
Psup Supply pressure
Pout Output pressure
-