12 VAC D300 PSS EVE0105 A-(en)
FUNCTIONAL SPECIFICATIONS for basic device
4-20 mA Intelligent without communication and ATEX approval
Signal Input
Two wire system
Reverse polarity protection feature
Signal range ............4to20mA
Operating range..........3.6to21.5mA
Input voltage ............DC8.5to36V
1)
(unloaded)
Load ..................300Ohms,6Vat20mA
With applications without communication the capacity
parallel to input may not be higher than 100 µF.
Start-uptime ............approx. 3 sec
Interruption time without power down:
withLCD+LED........typ.80ms
2)
Configuration
Local..................withlocalpushbuttons
Display.................multi-lingual graphic LCD or
five LEDs
The standard positioner i with LCD contains three
menu languages.
Standard menu languages:
- English - German
Freely selectable third language:
- French - Portuguese - Spanish
- Italian - Swedish - ...
(further menu languages on request)
The third menu language has to be selected and specified
with the order, otherwise standard: Spanish.
The third, freely selectable menu language can be modified
to another language by means of the configuration software
PC20/PC50.
*) Under development
1) On request we can specify higher voltage limits
2) Worst case conditions 4-20mA, with position feedback option, i/p-output
with max. current
Electrical classification hereto:
4) 5)
(Electronics family AI 638 per EC- Certificate of
Conformity PTB 00 ATEX 2128)
see Certificates of Conformity EX EVE0105 A
Type of protection “intrinsically safe”
TypeAI638GH..........II2GEExiaIIB/IIC,
II 2 G EEx ib IIB/IIC
Temperature classes
T4 with explosion protection code EAA
CertificateofConformity....PTB00ATEX2128
For use in hazardous areas in circuits certified as intrinsic-
ally safe with the following maximum values:
Input circuit:
Umax=30V,Imax=130mA,Pmax=0.9W
Li = negligible, Ci = 1.3 nF (5.3 nF to ground)
Ambient temperature ranges:
TemperatureclassT4: ....-40°Cto+80°C(-40 to 176ºF)
Type of protection FM “intrinsic safety”
ClassI,Div.1,GroupsA,B,C,D;
hazardous locations indoor and outdoor, NEMA Type 4X *)
Type of protection FM “non-incendive”
ClassI,Div.2,GroupsA,B,C,D,F,G;
hazardous locations indoor and outdoor, NEMA Type 4X *)
Type of protection CSA “intrinsic safety” *)
ClassI,Div.1,GroupsA,B,C,D;
hazardous locations indoor and outdoor, NEMA Type 4X
3) With this version “intelligent without communication” this is only possible
with EDC82 modem.
4) With appropriate order only
5) National requirements must be observed
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 25 26

Comentários a estes Manuais

Sem comentários