PSS EVE0105 A-(en) VAC D300 9
FUNCTIONAL SPECIFICATIONS for basic device with
communication FoxCom and FM / CSA approval
With FoxCom communication :
Operating mode digital
Input
Two-wire system, digital
Reverse polarity protection . . standard feature
Signal .................Digital
Supply voltage ...........DC13to36V
Supply current ...........~9mAat24V
Communication signal .....FoxComdigital, 4800 Baud,
FSK (Frequency Shift Key),
modulated on supply voltage
Input impedance Zi........~500Ohms(0.5to20kHz)
Cable capacitances (< 100 µF), inductances and impe-
dance of other attached devices must be conformal for
FOXBORO specification.
Configuration:
local ..................with3localkeysandLEDs
Software ...............PC20/IFDC
Hardware...............Modem PC10
I/A Series System ........FBM43incombination with
CP40
1)
(CP60 on request),
and FBM 243, 246 in
combination with CP60
1)
Operating mode analog
Input
Two-wire system
Reverse polarity protection . . standard feature
Signal range ............4to20mA
Operating range..........3.6to21.5mA
Input voltage ............DC13to36V
max. Load ..............650Ohm,13Vat20mA
Communication signal .....FoxComanalog, 600 Baud,
FSK (Frequency Shift Key),
modulated on 4 to 20 mA
Input impedance Zi........~500Ohm(0.5to20kHz)
Configuration:
local ..................with3localkeysandLEDs
Indication ...............5LEDs
Software ...............PC20/IFDC
Hardware...............Modem PC10
I/A Series System ........FBM44incombination with
CP40
1)
(CP60 on request),
and FBM 244 in combination
with CP60
1)
Others on request
Test sockets
- for connection of communicators
- for non-interruptable current measurement at
Code K, F, E; interlock diode can be switched off
Electrical classification hereto:
2) 3)
(Electronics family BIA 637: FM 3003731, CSA 1001984
and CSA 1001988)
see Certificates of Conformity EX EVE0105 A
Type of protection FM “intrinsic safety”
(Electronics family per FM 3003731)
Class I, Div. 1, Groups A, B, C, D; hazardous locations
indoor and outdoor, NEMA Type 4X
Type of protection FM “non-incendive”
(Electronics family per FM 3003731)
Class I, Div. 2, Groups A, B, C, D, F, G; hazardous
locations indoor and outdoor, NEMA Type 4X
Type of protection CSA “intrinsic safety”
(Electronics family per CSA 1001984 and CSA 1001988)
Class I, Div. 1, Groups A, B, C, D; hazardous locations
indoor and outdoor, NEMA Type 4X
*) Under development
1) Check CP for suitable ECBs
2) With appropriate order only
3) National requirements must be observed