SPA 1500
Installation instructions
96106-000-IN Installation instructions.doc
Page 4 of 9
7 INSTALLATION OF EQUIPMENT
7.1 Central Equipment
All central cabinets shall be installed in accordance with applicable Layout Drawings and
Equipment Arrangement Drawings.
Care shall be taken while installing the equipment not to cause any unnecessary damage
due to unfamiliarity of the equipment.
7.2 Installation of Field Equipment
General
All field equipment, such as Loudspeakers, Beacons, Access Panels etc. shall be installed in
accordance with applicable Data sheets, Layout Drawings and Equipment Arrangement
Drawings. A document revision check shall be carried out to ensure that the work packages
contain the latest issue of the drawings/documents.
Any equipment installed outdoors and left in a turned off condition must be properly weather
proofed as per manufacturers manuals. Weather proofing shall ensure that no excess humidity
or water enters the equipment causing corrosion.
General Location Rules
Equipment should be located in accordance with the following requirements:
Protected against damage.
Protected against vibration.
Operability and serviceability.
Display instruments and flashing lights to be legible and visible from main access areas.
Accessibility for maintenance without scaffolding.
Electrical equipment should not be located in open deck areas.
Equipment, which has to be installed in exposed areas, should be sheltered by use of
enclosures.
When Junction Boxes are installed in exposed areas, drain plugs shall be installed.
Final location shall be selected to avoid interference with escape routings, walkways, other
equipment, pipes, etc. and obstruction against activities related to transport and lifting
operations.
Heavy equipment should not be supported on pipe work, handrails, access ladders or cable
ladders.
Equipment located in areas which do not allow for maintenance accessibility as required,
should be installed on brackets which are arranged such that the equipment can be rotated,
raised or lowered into areas where maintenance can take place without the need for scaffolding.
Junction Boxes
Local Junction Boxes should be installed directly on steel supports adjacent to the equipment.
The junction boxes shall be installed so that they are easily accessible.
Area Junction Boxes shall be installed in accordance with the functional requirements
discussed above.
Access Panels
Access Panels, which are not installed in consoles/cabinets/racks/etc. but are to be field
mounted, shall be located approximately 1.5 m above deck/floor.
Handbook page
19/94