SPA 1500
Operating instructions
08100-005-OI
Page 5 of 5
2 ALARMS (option)
The SPA system may comprise an alarm tone generator board. (Option). This board has up
to three different alarm types.
Active alarms are indicated on the SPA 1500 STATUS panel by the ALARM led.
The alarm tone generator board will always be installed if the system includes GA.
2.1 Alarm activation / Reset
The alarms may be automatically activated / reset from an external system (F&G panel).
Alternatively an alarm control panel SPA 1503 / 1505 may be connected for manual
control and indication.
2.2 Alarm priority
The alarm signal has normal priority below any PA, but above Entertainment. This ensures
any Public Announcements to be heard at any time.
The alarm will however temporarily override any ongoing PA when initiated, but the user
may immediately regain access by reactivating the TALK button.
Ref. figure 3 for illustration.
Figure 3 – Alarm control panels SPA 1503 and 1505
Handbook page
15/94