TM 11-6625-2611-12
Table 3-1. Operator's Controls, Indicators, and Connectors (Continued)
Figure
9-1
index No.
20
21
22
23
24
25
3-6
Control, indicator,
or
connector
CHAL WIDTH SELECT switch
CHAL WIDTH VARY control
MAIN ATTEN control
CHAL ISLS SPACING SELECT switch
CHAL ISLS SPACING VARY control
CHAL INHIB
Function
2
Mode 2 challenge video
31A
Mode 3/A challenge video
C
Mode C challenge video
TEST Test mode challenge video
4A
Mode 4 maintenance word A challenge video. Also
enables operation of functions to MODE 4 con-
nector.
4B
Mode 4 maintenance word B challenge video. Also
enables operation of functions to MODE 4 con-
nector.
CW
Provides cw rf output for use during selectivity
measurements.
DUAL WA
Provides two mode 3/A interrogations. Spacing be-
tween first and second interrogations is con-
trolled by SCOPE TRIG/FREQ MEAS DELAY
(USEC) controls. For proper operation, SCOPE
TRIG/FREQ MEAS DELAY (USEC) controls
must be set to delay greater than 30
µ
sec. DUAL
3/A is used to check transponder recovery time.
Five-position rotary switch used to select challenge rf pulse width.
Switch position
Function
0.25
Sets challenge rf pulse width
to
0.25
µ
sec.
0.50
Sets challenge rf pulse width to 0.50
µ
sec.
(Nominal pulse width for mode 4 challenge rf.)
0.80
Sets challenge rf pulse width to 0.80
µ
sec (Nominal
pulse width for SIF challenge rf.)
1.70
Sets challenge rf pulse width to 1.70 µ sec.
VARY
Width of challenge rf pulses is controlled by CHAL
WIDTH VARY control.
Provides continuous adjustment of challenge rf pulse width, from less than
0.25 to at least 1.7
µ
see, when CHAL WIDTH SELECT switch is in
VARY,
Used to determine level of output rf signal at RF IN/OUT MAIN jack. Out-
put level is variable from -10 to -90 dBm. Control is calibrated in dBm.
Six-position rotary switch used to control positioning of ISIS pulse. Active
when CHAL INHIB switch is set to ISIS ON.
Switch position
Function
-.60
Positions ISLS pulse 0.60
µ
sec ahead of nominal
position.
-.15
Positions ISLS pulse 0.15
µ
sec ahead of nominal
Position.
o
Positions ISLS pulse at nominal position.
+.15
Positions ISLS pulse 0.15 µ sec after nominal posi-
tion.
+ .60
Positions ISLS pulse 0.60
µ
sec after nominal posi-
tion.
VARY
Position of ISLS pulse is controlled by CHAL ISLS
SPACING VARY control.
Provides continuous ±1 µ sec adjustment of ISLS pulse position, when
CHAL ISLS SPACING SELECT switch is set to VARY.
Three-position toggle switch used to control generation of ISLS pulse (SIF
or mode 4) or disparity pulse (Mode 4 only).
Switch position
Function .
DISPARITY (MOM) Momentary position inhibits pulse in 66
µ
sec posi-
tion of MODE 4 challenge rf, enables a disparity
pulse to disparity output of MODE 4 connector ‘
-
and inhibits three-pulse reply output of MODE 4
connector,
OFF
No ISLS or disparity pulses are generated.
ISLS ON
Enables ISLS pulse to be inserted into challenge rf
(SIF or mode 4), provides a disparity pulse (mode
-
4 only) to disparity output MODE 4 connector
and inhibits three-pulse reply output from
Comentários a estes Manuais