TM 11-6625-2611-12
Table 3-1. Operator’s Controls, Indicators, and Connectors (Continued)
Figure
3-1
index No
5
6
7
8
9
10
11
3-4
Control, indicatar,
or
connector
SCOPE TRIG/FREQ MEAS DELAY (USEC) MULT
control
MEASUREMENT MKRS OUT jack
MEASUREMENT MKR PHASING control
MEASUREMENT SCOPE TRIG OUT jack
MEASUREMENT DEMOD VIDEO LEVEL control
MEASUREMENT DEMOD VIDEO OUT jack
MEASUREMENT FUNCTION SELECT (4-position
rotary) switch
Function
tion between mode 3/A challenges.
Switch position
Function
OFF
X0.4
X4
X40
X400
Neither scope trigger nor challenge video is
delayed. Scope trigger occurs 27
µ
sec before P3
pulse when CHAL MODE SELECT switch is set
to 1, 2, 3/A, TEST, or DUAL 3/A. Scope trigger
occurs 2
µ
sec before first pulse of challenge
video when CHAL MODE SELECT switch is set
to 4A or 4B.
Scope trigger or challenge video is delayed 0.4 to
4.4
µ
sec as controlled by SCOPE TRIG/FREQ
MEAS DELAY (USEC) MULT control.
Scope trigger or challenge video is delayed 4 to 44
µ
sec as controlled by SCOPE TRIG/FREQ
MEAS DELAY (USEC) MULT control.
Scope trigger or challenge video is delayed 40 to
440
µ
sec as controlled by SCOPE TRIG/FREQ
MEAS DELAY (USEC) MULT control.
Scope trigger or challenge video is delayed 400 to
4400
µ
sec position as controlled by SCOPE
TRIG/FRIQ MEAS DELAY (USEC) MULT con-
trol.
Varies delay of scope trigger or challenge video within range set by SCOPE
TRIG/FREQ MEAS DELAY (USEC) RANGE switch.
Provides SIF reply markers for measuring SIF reply spacing or frequency
markers used to measure frequency of rf. When CHAL MODE SELECT
switch is in any position and SIG GEN FCTN switch is set to FIXED
FREQ, SIF reply markers are provided at 0,20.30,24.65, and 49.30
µ
sec.
SIF reply markers are accurate within ±0.02
µ
sec. When SIG GEN
FCTN switch is set to SWP ±5 MHZ, frequency markers corresponding
to radiofrequencies of 0, ±1, ±3, and
±5
mHz are provided. The fre-
quency markers are accurate within ±0.1 MHz. The SIG GEN FCTN
switch is set to SWP ±20 MHZ, the markers of which represent, 0, ±1,
±3, ±5, and ±20 mHz.
Varies position of SIF reply markers
±
1
µ
sec when present at the
MEASUREMENT MKR OUT jack. Nominal position of SIF reply
markers correspond to nominal position of transponder SIF reply.
Provides scope trigger signals for use by external oscilloscope. Scope trig-
ger signal is 5 ± 1.0 volts in amplitude and 3.0 ±2.0 µ sec wide when ap-
plied to a 100-ohm load.
Adjusts amplitude of signal at MEASUREMENT DEMOD VID OUT jack
when MEASUREMENT FUNCTION SELECT switch is set to PWR.
When adjusted so that signal at MEASUREMENT DEMOD VID OUT
jack is 1.0 volt in amplitude, MEASUREMENT meter indicates peak
power of rf signal applied to the RF IN/OUT jacks. Peak power of signal
applied to LOW PWR MEAS IN jack can also be determined in conjunc-
tion with calibration chart packed in front panel cover and illustrated in
figure 3-2. The chart converts meter indication into actual power being
measured.
Provides test set video output for display on external oscilloscope.
Selects type of measurement to be made with test set.
Switch position
PRF CHAL
PRF REPLY
PWR
Function
MEASUREMENT meter indicates prf of challenge
video generated by test set.
MEASUREMENT meter indicates prf of reply
video from transponder under test.
Sets test set to measure peak power of input rf sig-
nal. When MEASUREMENT DEMOD VIDEO
LEVEL control is adjusted so that signal at
MEASUREMENT DEMOD VID OUT jack is 1.0
volt in amplitude, MEASUREMENT meter indi-
cates peak power of rf signal applied to the RF