Directed Electronics Valet 561T Guia de Instalação Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 34
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 22
© 2005 Directed Electronics, Vista, CA—all rights reserved
2233
iinntteerrnnaall pprrooggrraammmmiinngg jjuummppeerr
This jumper is used to determine the light flash output. In the (+) position, the on-board relay is enabled and
the unit will output (+)12V on the H1/11 WHITE wire. In the (-) position, the on-board relay is disabled. The
H1/11 WHITE wire will supply a (-) 200 mA output suitable for driving factory parking light relays. To access the
jumper, open the control module.
NNOOTTEE::
For parking light circuits that draw 10 amps or more, the internal jumper must be switched
to a (-) light flash output. P/N
88661177
or a standard automotive SPDT relay must be used on the
H1/11 light flash output harness wire.
lliigghhtt ffllaasshh jjuummppeerr
NOTE: JUMPER IS
INSIDE THE CASE
Vista de página 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 33 34

Comentários a estes Manuais

Sem comentários