Data Output Formats for the “Draft Shield Status”
These depend on the particular menu code setting:
code 7 2 1 “without data ID code” = data output with 16 characters,
or code 7 2 2 “with data ID code” = data output with 22 characters
Data Output Format with 16 Characters
Data Output Format with ID Code (22 Characters)
With this format, the ID code “Stat” is output in the1st through the 4th places.
*
= space
The draft shield status consists of control codes and the turning angle of the
draft shield. The control codes are identified as xx, and the turning angle
is designated as yyy.
xx = Control Codes for the Draft Shield
The decimal values of bits 0 through 6 are added for the following control
codes and output as a decimal number:
Decimal Binary Control code
value value
0 Bit 0 = 0 No control error
1 2
0
Bit 0 = 1 Control error
0 Bit 1 = 0 Draft shield motor “off”
2 2
1
Bit 1 = 1 Not implemented
0 Bit 2 = 0 Not implemented
4 2
2
Bit 2 = 1 Motorized draft shield, as far as it will turn
0 Bit 3 = 0 “Self-teaching” function off
8 2
3
Bit 3 = 1 “Self-teaching” function on
0 Bit 4 = 0 Open draft shield
1
)
16 2
4
Bit 4 = 1 Closed draft shield
1
)
0 Bit 5 = 0 Slow speed
1
)
32 2
5
Bit 5 = 1 Fast speed
1
)
0 Bit 6 = 0 Motorized draft shield operation
64 2
6
Bit 6 = 1 Manual draft shield operation
1
) = These control codes refer to the previous movements of the draft shield door.
12345678910111213141516171819 2021 22
Stat
********
W
*
0 X X Y Y Y CR LF
12345678910111213141516
******
W
*
0 X X Y Y Y CR LF
4–11