Weighing in Percent with Additional Requirements
Changing the Reference Percentage
The reference percentage setting is shown on the application display above
the unit symbol after you have pressed c.
You can change the reference percentage to suit your individual requirements
in one of the following ways:
– Enter a percentage using the numeric keys and store it by pressing F identified
on the display by “STO REF”
or
– Change the percentage in the parameter mode
To select
the parameter mode: – Hold down i for more than 2 seconds
To select the percentage: – Press ^ - f
If you have made a mistake and need to reset
the percentage, simply press the c key
To store the percentage
– temporarily until you
turn off the balance: – briefly press STO - F
– permanently after you
turn off the power (in the
non-volatile memory): – press STO - F for more than 2 seconds
This setting is not cancelled by the reset code 9 – – 1°!
Reference Percentage
Changing the reference percentage Code
No change 2 3 1
In cycles: 5,10, 20, 50, 100, 5,10, ... 2 3 2*
In increments of one 2 3 3
Storage Parameter for the Reference Weight
(Code only for models MC 210 S (-0CE), MC 210 P (-0CE), MC 410 S (-0CE))
The reference weight is stored Code
with full accuracy according to the internal resolution 3 5 1
according to the display accuracy 3 5 2*
* = factory setting
3–49