Directed Electronics 3200HS Especificações

Consulte online ou descarregue Especificações para não Directed Electronics 3200HS. Directed Electronics 3200HS Product specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Application Note
www.renesas.com
All information contained in these materials, including products and product specifications,
represents information on the product at the time of publication and is subject to change by
Renesas Electronics Corp. without notice. Please review the latest information published by
Renesas Electronics Corp. through various means, including the Renesas Electronics Corp.
website (http://www.renesas.com).
February 13, 2012
R01AN0168ED0101, Rev. 01.01
V850E2/Dx4
32-bit Microcontroller
Intelligent Stepper Motor (ISM) Function
32
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - V850E2/Dx4

Application Notewww.renesas.comAll information contained in these materials, including products and product specifications, represents information on

Página 2 - Application Note

R01AN0168ED0101 Rev. 01.01 10Application NoteChapter 2 General Notices 2.2.3 Functionality of GEN (Soft Reset)GEN is always set on Hardware RESET.By

Página 3

R01AN0168ED0101 Rev. 01.01 11Application Note Chapter 3 About Stepper Motor Movement3.1 The Physics of a Stepper MotorThe Stepper Motor consists of

Página 4

R01AN0168ED0101 Rev. 01.01 12Application NoteChapter 3 About Stepper Motor Movement The average amplitude of the magnetic field is determined by the

Página 5

R01AN0168ED0101 Rev. 01.01 13Application NoteChapter 3 About Stepper Motor Movement 3.2 The PWM Generation of ISMFollowing a Prescaler (GTB), the cen

Página 6

R01AN0168ED0101 Rev. 01.01 14Application NoteChapter 3 About Stepper Motor Movement 3.2.1 ISM ClockingThe clock of the central time base is selected

Página 7

R01AN0168ED0101 Rev. 01.01 15Application NoteChapter 3 About Stepper Motor Movement 3.3 Recirculation of InductanceRecirculation means performing a s

Página 8

R01AN0168ED0101 Rev. 01.01 16Application NoteChapter 3 About Stepper Motor Movement 3.4 The ISM Channel CircuitryAs a summary of the previous chapter

Página 9 - Chapter 2 General Notices

R01AN0168ED0101 Rev. 01.01 17Application Note Chapter 4 Automated Motor MovementWithin this chapter, more deep functional description about the proc

Página 10

R01AN0168ED0101 Rev. 01.01 18Application NoteChapter 4 Automated Motor Movement 4.1 Processing of PWM (non-ZPD) ChannelsThis is performed for all cha

Página 11

R01AN0168ED0101 Rev. 01.01 19Application NoteChapter 4 Automated Motor Movement CZCn has reached the end of the table marked by ZPD table index limit

Página 12

2 R01AN0168ED0101Application Note Notice1. All information included in this document is current as of the date this document is issued. Such inform

Página 13 - 3.2 The PWM Generation of ISM

R01AN0168ED0101 Rev. 01.01 20Application NoteChapter 4 Automated Motor Movement Figure 4-2 ZPD Processing Flow of ISM=3'3URFHVVLQJRI&KDQQ

Página 14 - 3.2.2 PWM Output Generation

R01AN0168ED0101 Rev. 01.01 21Application NoteChapter 4 Automated Motor Movement 4.3 Channel Management Processing OverviewSummarized from the chapter

Página 15

R01AN0168ED0101 Rev. 01.01 22Application Note Chapter 5 Looking into the PWM and ZPD Tables5.1 Virtual ChannelsAs the PWM Value RAM is a lookup-tabl

Página 16 - 3.4 The ISM Channel Circuitry

R01AN0168ED0101 Rev. 01.01 23Application NoteChapter 5 Looking into the PWM and ZPD Tables 5.2 Values for PWM Operation5.2.1 Channels and PrecisionAs

Página 17 - Selection

R01AN0168ED0101 Rev. 01.01 24Application NoteChapter 5 Looking into the PWM and ZPD Tables 5.2.2 PWM ValuesIn the ideal case, one would expect that t

Página 18

R01AN0168ED0101 Rev. 01.01 25Application NoteChapter 5 Looking into the PWM and ZPD Tables (1) Example of a Sine - Cosine Sequence PWM TableWhen writ

Página 19

R01AN0168ED0101 Rev. 01.01 26Application NoteChapter 5 Looking into the PWM and ZPD Tables { 0x3E0L, 0x0F8L, 0x3L, 1L, 1L, 0L }, { 0x3EBL, 0x0C7L,

Página 20 - R01AN0168ED0101 Rev. 01.01 20

R01AN0168ED0101 Rev. 01.01 27Application NoteChapter 5 Looking into the PWM and ZPD Tables { 0x3FDL, 0x032L, 0x1L, 1L, 1L, 0L }, { 0x3FFL, 0x000L,

Página 21

R01AN0168ED0101 Rev. 01.01 28Application NoteChapter 5 Looking into the PWM and ZPD Tables 5.3 Values for ZPD Operation5.3.1 Addressing in ZPD ModeWh

Página 22 - 5.1 Virtual Channels

R01AN0168ED0101 Rev. 01.01 29Application Note Chapter 6 Performing MovementsWithin this section, the movement of stepper motors using the Channel Ma

Página 23 - 5.2 Values for PWM Operation

3 R01AN0168ED0101Application Note The quality grade of each Renesas Electronics product is “Standard” unless otherwise expressly specified in a Ren

Página 24 - 5.2.2 PWM Values

R01AN0168ED0101 Rev. 01.01 30Application NoteChapter 6 Performing Movements 6.1.1 Common 25-bit Number FormatFor all parameters and variables which a

Página 25

R01AN0168ED0101 Rev. 01.01 31Application NoteChapter 6 Performing Movements (2) Value IntegerFor position values, the value integer consists of the m

Página 26 - R01AN0168ED0101 Rev. 01.01 26

R01AN0168ED0101 Rev. 01.01 32Application NoteChapter 6 Performing Movements (3) Acceleration Limit, Deceleration Limit PALn, PDLnIf acceleration or d

Página 27 - R01AN0168ED0101 Rev. 01.01 27

R01AN0168ED0101 Rev. 01.01 33Application NoteChapter 6 Performing Movements 6.1.3 Variable Description(1) Actual Algorithm Values VAXn, VASn, VAPnThe

Página 28 - 5.3 Values for ZPD Operation

R01AN0168ED0101 Rev. 01.01 34Application NoteChapter 6 Performing Movements }}if ( VAS >= 0 ){if ( VAS > PMS ) {VAS = PMS}}else{if ( ( -VAS

Página 29 - 6.1 Parameters and Variables

R01AN0168ED0101 Rev. 01.01 35Application NoteChapter 6 Performing Movements VSP = 0}else{VSP = VSP}if ( ( ( -VAS ) >= PS3 ) and( ( -VAS ) <= PS

Página 30

R01AN0168ED0101 Rev. 01.01 36Application NoteChapter 6 Performing Movements 6.2 Moving the MotorsHaving all parameters set, the timebases defined and

Página 31 - 6.1.2 Parameter Description

R01AN0168ED0101 Rev. 01.01 37Application Note Chapter 7 Performing Zero Point Detection7.1 Zero Point Detection (ZPD) TheoryIn order to define the Z

Página 32

R01AN0168ED0101 Rev. 01.01 38Application NoteChapter 7 Performing Zero Point Detection 7.1.1 The ZPD Measurement PrincipleFor all 4 cases, the same m

Página 33 - 6.1.4 Algorithm Code

R01AN0168ED0101 Rev. 01.01 39Application NoteChapter 7 Performing Zero Point Detection Figure 7-3 Reaching the Zero PointIn the best case, the induce

Página 34 - R01AN0168ED0101 Rev. 01.01 34

4 R01AN0168ED0101Application Note 12. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written co

Página 35 - R01AN0168ED0101 Rev. 01.01 35

R01AN0168ED0101 Rev. 01.01 40Application NoteChapter 7 Performing Zero Point Detection Figure 7-4 Using the Blanking Time(4) Definition of the Measur

Página 36 - 6.2 Moving the Motors

R01AN0168ED0101 Rev. 01.01 41Application NoteChapter 7 Performing Zero Point Detection (5) Setting up the Digital Filter of ZPDThe digital filter of

Página 37

R01AN0168ED0101 Rev. 01.01 42Application NoteChapter 7 Performing Zero Point Detection Note In most cases, the reference level on its own is enough t

Página 38 - This is our

R01AN0168ED0101 Rev. 01.01 43Application NoteChapter 7 Performing Zero Point Detection For each channel, one of its four ports can be assigned by ZIS

Página 39 - Zero Point

R01AN0168ED0101 Rev. 01.01 44Application NoteChapter 7 Performing Zero Point Detection required. So, we choose GZF to be 14 (factor 1/512), and we ar

Página 40 - Measurement Time: 14 ms

R01AN0168ED0101 Rev. 01.01 45Application NoteChapter 7 Performing Zero Point Detection 7.3 ZPD OperationThe ZPD operation for a channel can be indivi

Página 41 - Reference

R01AN0168ED0101 Rev. 01.01 46Application NoteChapter 7 Performing Zero Point Detection 7.3.1 Using Direct I/O ControlWhen performing ZPD, it is often

Página 42 - 7.2 The ZPD Function Settings

R01AN0168ED0101 Rev. 01.01 47Application NoteChapter 7 Performing Zero Point Detection 7.3.2 Executing a ZPD TableThe following illustration shows, h

Página 43 - Measurement Cycle = 1/f

R01AN0168ED0101 Rev. 01.01 48Application NoteChapter 7 Performing Zero Point Detection The following chapters are referring to the steps indicated wi

Página 44

R01AN0168ED0101 Rev. 01.01 49Application Note Revision HistoryThe table below gives an overview about the revision history of this document.Rev. Dat

Página 45 - 7.3 ZPD Operation

R01AN0168ED0101 Rev. 01.01 5Application Note General Precautions in the Handling of MPU/MCU ProductsThe following usage notes are applicable to all M

Página 46 - H-FET Bridge

V850E2/Dx4 Application NotePublication Date: Rev. 01.01 February 13, 2012Published by: Renesas Electronics Corporation

Página 47 - )LUVW6WHSV

http://www.renesas.comRefer to "http://www.renesas.com/" for the latest and detailed information.Renesas Electronics America Inc. 2880 Scot

Página 48

R01AN0168ED0101 V850E2/Dx4

Página 49 - Revision History

R01AN0168ED0101 Rev. 01.01 6Application Note Table of ContentsGeneral Precautions in the Handling of MPU/MCU Products . . . . . . 5Table of Conten

Página 50 - Rev. 01.01 February 13, 2012

R01AN0168ED0101 Rev. 01.01 7Application NoteTable of Contents 6.2 Moving the Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 51 - Colophon 1.0

R01AN0168ED0101 Rev. 01.01 8Application Note Chapter 1 Overview of ISM in the Dx4-H SeriesWithin the Dx4-H series, the Intelligent Stepper Motor (IS

Página 52

R01AN0168ED0101 Rev. 01.01 9Application Note Chapter 2 General Notices2.1 Abbreviations in this Application NoteTypically, all variables and registe

Comentários a estes Manuais

Sem comentários