GOSSEN Mueller & Weigert 13
Order Example:
Moving-Coil Ammeter for AC 96 x 96 mm, 100/5 A Transformer Ratio
Order No.: 3200W BG16 CG100
Front Dim. in mm
48 x 48 72 x 72 96 x 96 144 x 144
Type
DG 48 DG 72 DG 96 DG 144
Order no. 3100W 3150W 3200W 3250W
(in prep.)
Meas. Input Alt. Current Connection Current
rated value 100% direct 1.2 A
1)
CC1,2 +++
+
6 A
1)
CC6 +++
+
rated value 120% at transformer sec.: 1 A
1)
primary current: ... A
BG15 CG ... +++
+
primary current: ... kA
BG15 CH ... +++
+
at transformer sec.: 5 A
1)
primary current: ... A
BG16 CG ... +++
+
primary current: ... kA
BG16 CH ... +++
+
Meas. Input Alt. Voltage Connection Voltage (upper range value)
rated value 100% direct 60V/100V/120V/150V/
DC60 +++
+
250V/300V/400V/
to
+
2)
++
+
500V/600V
DC600
+
2)
++
+
rated value 120% at transformer sec.: 100 V primary voltage: ... V
BG20 DG ... +++
+
primary voltage: ... kV
BG20 DH ... +++
+
at transformer sec.: 110 V primary voltage: ... V
BG21 DG ... +++
+
primary voltage: ... kV
BG21 DH ... +++
+
Scale Graduation corresponds to measuring range
−+++
+
without scale
GL95
+++ +
blank scale, lower and upper value markings, company logo, symbols
GL98 +++
+
Position of use standard
+++
+
0 ... 45 degrees from horizontal (bonded glass faceplate) LA11 +++ +
46 ... 89 degrees from horizontal (bonded glass faceplate) LA12 +++ +
91 ... 135 degrees from horizontal
LA13
+
++ +
Applications standard
−+++
+
conditionally tropic-proof, climatic category 3
LB4 +++
+
Protection standard
+++
+
front panel: IP 54, terminals: IP00
LH21
+++
+
Resistance To Vibration/ standard
−+++
+
Marine Applications vibration resistance: 2.5 g, shock resistance: 30 g
LN56 +++
+
marine applications, German Lloyds
LN8 +++ +
Operating Voltage standard
−+++
+
600 V (600 V CAT lll) LS9 +−
3)
3)
3)
Bezel dull black
−+++
+
dull grey, RAL 7037
MA11 +++
+
Glass Faceplate standard
−+++
+
anti-glare
MG1 +++
+
anti-glare, with red adjustable set pointer
MG98 +++
+
Housing and Fasteners standard
−+++
+
sheet metal housing with type S screw clamp
ML7
++
sheet metal housing with type B screw clamp
ML8
++
polycarbonate housing with 2 leaf springs
ML9 +++
polycarbonate housing with Subklew fasteners
ML10 +++
polycarbonate housing with 4 leaf springs
ML11 +++
polycarbonate housing with mounts for H&B Unibloc grid
ML12 +
4)
4)
5)
polycarbonate housing for manual grid mount, no fasteners
ML5 +
4)
4)
5)
Identification none
−+++
+
at rear: ............
MZ998 ... +++
+
Scale Inscription none
−+++
+
(Latin lettering) 18 characters, 1 line: .......... (not possible for 2
nd
inscription)
SM903 ... +
−−
22 characters, 1 line: ..........
SM902 ...
++
+
37 characters, 2 lines: 1
st
line (15 char.): ..., 2
nd
line (22 char.): ....
SM911 ...
++
+
Additional Numberings none
−+++
+
2
nd
set of numberings, black: ...
SK982 ... +++
+
2
nd
set of numberings, red (RAL 2002): ...
SK983 ... +++
+
Red Marker (RAL 2002) none
−+++
+
red marker at: ...
ST981 ... +++
+
Order Number Instructions:
1) Type DG 48 with separate matching transformer
2) See “Safety Precautions” on page 8 regarding operating and nominal voltages.
3) Standard model
4) Use order number ML9 for H&B Unibloc and manual grids.
5) Standard model is suitable.
Select one model each for order numbers with the same sequence of letters.
No additional entries required for std. models (identified with bold typeface and “” in order no. column).
An entry with “....” in the order no. column means that the order number must be supplemented with text.
+
+
Square Panel Meters
for Alternating Current or Alternating Voltage
Order Information
Code: B0
Vista de página 12