1
© 1999 Directed Electronics, Inc. N429 9/99
PC Programmable
Rapid Resume Logic
Owner Recognition
PART NO. 429
TTAABBLLEE OOFF CCOONNTTEENNTTSS
429 SERIES
What Is Included . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation Points to Remember . . . . . . . . . . . . . .2
Harness Diagrams . . . . . . . . . . . . . . . . . . . . . . . . .3
Primary Harness . . . . . . . . . . . . . . . . . . . . . 3
Wire Connection Guide . . . . . . . . . . . . . . . . . . . . .4
H1 Primary Harness . . . . . . . . . . . . . . . . . 4
H2 Harness, Door Lock Outputs . . . . . . . . . .7
Door Lock Wiring Guide . . . . . . . . . . . . . . . . . . . . .8
Positive-Triggered, Relay Driven
Systems (Type A) . . . . . . . . . . . . . . . . . . . . .8
Negative-Triggered, Relay Driven
Systems (Type B) . . . . . . . . . . . . . . . . . . . . .9
Reversing Polarity (Type C) . . . . . . . . . . . .10
After-market Actuators (Type D) . . . . . . . . .11
Electrically Activated Vacuum (Type E) . . . .11
One-Wire System, (Type F) . . . . . . . . . . . .12
Plug-In Harnesses . . . . . . . . . . . . . . . . . . . . . . . .13
Super Bright LED . . . . . . . . . . . . . . . . . . . .13
Valet
®
/Program Switch . . . . . . . . . . . . . . . .13
Programmer Interface . . . . . . . . . . . . . . . . .13
On-Board Dual Stage Shock Sensor . . . . . . . . . .13
Optional Four-Pin Shock Sensor Harness . . . . . .13
Internal Programming Jumper . . . . . . . . . . . . . .14
Light Flash . . . . . . . . . . . . . . . . . . . . . . . . .14
Bypassing Sensor Inputs . . . . . . . . . . . . . . . . . . .14
System Features Learn Routine . . . . . . . . . . . . . 15
Once a Feature is Programmed . . . . . . . . .16
To Access Another Feature In
The Same Menu . . . . . . . . . . . . . . . . . . . .16
To Select Another Menu . . . . . . . . . . . . . .16
To exit the learn routine . . . . . . . . . . . . . . .16
System Features Menus . . . . . . . . . . . . . . . . . . . 17
Menu #1-Basic Features . . . . . . . . . . . . . . .17
Menu #2-Advanced Features . . . . . . . . . . .17
Feature Descriptions . . . . . . . . . . . . . . . . . . . . . . 18
Basic Features . . . . . . . . . . . . . . . . . . . . . .18
Advanced Features . . . . . . . . . . . . . . . . . .19
Transmitter/Receiver Learn Routine . . . . . . . . . .20
Transmitter Configurations . . . . . . . . . . . . . . . . .22
Standard Configuration . . . . . . . . . . . . . . . .22
Expanded Configuration . . . . . . . . . . . . . . .22
Multi-Level Security Arming . . . . . . . . . . . . . . . . .23
Table of Zones . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Long-Term Event History . . . . . . . . . . . . . . . . . . .24
Optional Vehicle Recovery System . . . . . . . . . . . 24
Rapid Resume Logic . . . . . . . . . . . . . . . . . . . . . .25
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . 25
II
NNSSTTAALLLLAATTIIOONN
GG
UUIIDDEE
Directed Electronics, Inc.
®
Features:
Vista de página 0
1 2 3 4 5 6 ... 25 26

Resumo do Conteúdo

Página 1 - 429 SERIES

1© 1999 Directed Electronics, Inc. N429 9/99• PC Programmable• Rapid Resume Logic• Owner RecognitionPART NO. 429TTAABBLLEE OOFF CCOONNTTEENNTTSS429

Página 2 - WHAT IS INCLUDED

10© 1999 Directed Electronics, Inc. N429 9/99Type C: Reversing PolarityInterfacing with a reversing polarity system requires either two relays or one

Página 3

11© 1999 Directed Electronics, Inc. N429 9/99Type D: After-market ActuatorsIn order for this system to control one or more after-market actuators, a

Página 4 - WIRE CONNECTION GUIDE

12© 1999 Directed Electronics, Inc. N429 9/99Type F: One-Wire SystemThis system usually requires a negative pulse to unlock, and cutting the wire to

Página 5 - H1/6 BLUE

13© 1999 Directed Electronics, Inc. N429 9/99Super Bright LED, 2-pin white plugThe super bright LED operates at 2V DC. Make sure the LED wires are no

Página 6 - H1/9 YELLOW

14© 1999 Directed Electronics, Inc. N429 9/99LIGHT FLASH JUMPER:This jumper is used to determine the light flash output. In the (+) position, the on-

Página 7 - H1/12 RED/WHITE

15© 1999 Directed Electronics, Inc. N429 9/99The System Features Learn Routine™dictates how the unit operates. Due to the number of steps, they have

Página 8 - DOOR LOCK WIRING GUIDE

16© 1999 Directed Electronics, Inc. N429 9/99Once a feature is programmed:• Other features can be programmed within the same menu.• Another menu can

Página 9

17© 1999 Directed Electronics, Inc. N429 9/99Items in bold text have been programmed to the two chirps setting at the factory.Menu #1- Basic Features

Página 10 - Type C: Reversing Polarity

18© 1999 Directed Electronics, Inc. N429 9/99The features of the system are described below. If the system is being programmed with a DEI®Bitwriter™o

Página 11

19© 1999 Directed Electronics, Inc. N429 9/991-10 CODE-HOPPING™ON/OFF:The system uses a mathematical formula to change its code each time the trans-m

Página 12 - Type F: One-Wire System

This product represents many years of research and development. It is very sophisticated and should be installedby experienced security installers onl

Página 13 - PLUG-IN HARNESSES

20© 1999 Directed Electronics, Inc. N429 9/99The system comes with two transmitters that have been taught to the receiver. The receiver can store up

Página 14 - INTERNAL PROGRAMMING JUMPER

21© 1999 Directed Electronics, Inc. N429 9/99CHANNELS #4-6:Channels 4 through 6 are used to assign the arm, disarm and panic functions to separatebut

Página 15 - SYSTEM FEATURES LEARN ROUTINE

22© 1999 Directed Electronics, Inc. N429 9/99The transmitters can be programmed with the standard or single button arm/disarm configurations by using

Página 16 - To select another menu:

23© 1999 Directed Electronics, Inc. N429 9/99Multi-Level Security Arming is a feature that allows you to select which of the security system's i

Página 17 - SYSTEM FEATURES MENUS

24© 1999 Directed Electronics, Inc. N429 9/99The system stores the last two full triggers in memory.These are not erasable. Each time the unit sees a

Página 18 - FEATURE DESCRIPTIONS

25© 1999 Directed Electronics, Inc. N429 9/99To disarm VRS®(after siren has begun chirping):1. Turn the ignition to the ON position.2. Press and rele

Página 19

26© 1999 Directed Electronics, Inc. N429 9/99The Valet®switch doesn’t work.Is it plugged into the correct socket? Check the System Features Learn Rou

Página 20

PRIMARY HARNESS H1, 12-PIN CONNECTOR3© 1999 Directed Electronics, Inc. N429 9/99H1/1H1/2H1/3H1/4H1/5H1/6H1/7H1/8H1/9H1/10H1/11H1/12ORANGE (-) 500 mA

Página 21 - CHANNEL #9:

4© 1999 Directed Electronics, Inc. N429 9/99This guide describes in detail the connection of each wire. Also included are possible applications of ea

Página 22 - TRANSMITTER CONFIGURATIONS

5© 1999 Directed Electronics, Inc. N429 9/99H1/3 WHITE/BLUE200 mA (-) channel three output: This wire provides a 200 mA (-) output whenever the trans

Página 23 - MULTI-LEVEL SECURITY ARMING

6© 1999 Directed Electronics, Inc. N429 9/99H1/7 VIOLET(+) door trigger input: This type of dome circuit is used in many Ford products. Connect the v

Página 24 - LONG TERM EVENT HISTORY

7© 1999 Directed Electronics, Inc. N429 9/99H1/10 BROWN(+) siren output: Connect this to the red wire of the Revenger®siren. Connect the black wire o

Página 25 - RAPID RESUME LOGIC

8© 1999 Directed Electronics, Inc. N429 9/99Type A: (+) 12V pulses from the switch to the factory relaysThe system can control a Type A system direct

Página 26 - Status LED doesn’t work

9© 1999 Directed Electronics, Inc. N429 9/99Type B: (-) pulses from the switch to the factory relaysThis system is common in many Toyota, Nissan, Hon